The Client

Our client is a major UK infrastructure and engineering services provider responsible for maintaining essential infrastructure and public-sector facilities across the country. Its work spans utilities such as water, gas and electricity, alongside roads, railways, airports, social housing, defence, justice and education.

APS Safety Systems has worked in partnership with the organisation since 2013, developing a strong and trusted working relationship across a wide range of projects. APS is a preferred contractor for fall protection, safe access and lightning protection solutions, supporting the client with the inspection, design, installation and ongoing management of safety systems across its property portfolio.

As part of this long-standing relationship, APS was approached to support a programme of roof safety improvements across several schools, including a secondary school in Glasgow where the existing horizontal lifeline arrangements required replacement and upgrading.

Kee Line Installation for Secondary School Roof Safety in Glasgow - APS Safety 2

Background

A number of schools within the client’s portfolio were originally constructed before 2000 and contained ageing horizontal lifeline systems. As part of its ongoing lifecycle programme, the client wanted to replace and upgrade these existing systems with modern fall protection solutions.

Other schools within the portfolio had been constructed around 2008 and incorporated Latchways Constant Force systems. Some of these systems had experienced product failures and were therefore also scheduled for replacement as part of the wider lifecycle works.

For the Glasgow secondary school, the project presented an opportunity to do more than simply replace the existing horizontal lifeline system on a like-for-like basis.

APS reviewed how the roof was actually being used and identified opportunities to improve the system design so that maintenance personnel could safely reach all necessary rooftop areas, including locations where access using a Mobile Elevating Work Platform (MEWP) was not practical.

The objective was to provide a long-term solution that supported both fall protection and the practical maintenance requirements of the building.

The Brief

APS Safety Systems was tasked with developing a replacement horizontal lifeline system that would improve roof safety while meeting the client’s technical and operational requirements.

The new system needed to replace ageing or unsuitable fall protection equipment and provide a fully designed and engineered solution for future rooftop maintenance.

Compliance was also an important consideration. The client required a system designed to the relevant requirements of BS EN 795:2012 and CEN/TS 16415:2013, together with a new product warranty.

Just as importantly, the layout needed to work for the people using it.

Rather than simply following the route of the previous system, APS considered the location of access points, the areas requiring routine maintenance and the routes personnel would need to follow across the roof.

This approach allowed APS to develop a system that addressed the practical limitations of the previous arrangement while improving access to areas where alternative methods, such as a MEWP, could not be used.

The Solution

During the initial phase of the programme, APS had specified 3M DBI-SALA Roof Safe horizontal lifeline systems. However, before the works commenced, APS reviewed the specification and identified an opportunity to change the proposed system to Kee Line.

Thanks to the long-standing relationship between APS and the client, the team was able to present the reasons for recommending Kee Line and demonstrate how the system could satisfy the requirements of the project.

APS showed that the Kee Line product could meet the required standards while also providing the product warranties the client required. Following consultation, the revised specification was approved and APS proceeded with the Kee Line installation.

The horizontal lifeline system provides a permanent fall protection solution for authorised personnel carrying out inspection, servicing and maintenance activities on the school roof.

Most importantly, the system layout was developed around the actual maintenance requirements of the building rather than simply replicating the previous installation.

Improving Rooftop Maintenance Access

A key part of the project was ensuring that the new Kee Line installation provided practical access to all necessary rooftop maintenance areas.

APS considered existing roof access points, the location of equipment requiring servicing and the routes personnel would need to follow when working at height.

Particular attention was given to areas that could not easily be reached using a MEWP. The new system layout was designed to allow authorised users to access these locations while using the permanent fall protection system provided.

By approaching the project in this way, APS was able to enhance the overall design and provide a more useful solution for the end user.

The result was not simply a replacement for an ageing lifeline system, but a newly designed roof safety arrangement intended to support the school’s ongoing inspection and maintenance requirements.

The Outcome

The completed Kee Line installation at the Glasgow secondary school provides the client with a modern horizontal lifeline system designed around the requirements of both the building and its end users.

Replacing the existing equipment has provided a new system with an associated product warranty, while the redesigned layout improves access to the areas where maintenance teams need to work.

The system has also been fully designed, engineered and tested in line with the requirements established for the project.

For the client, one of the most significant benefits is the improved accessibility of the roof. Maintenance teams now have a permanent fall protection solution designed to provide access to the necessary working areas, including locations where other access methods may not be practical.

The project demonstrates the value of reviewing existing fall protection arrangements as part of lifecycle replacement works. Rather than automatically installing a new system in exactly the same configuration, assessing how the roof is used can identify opportunities to improve safety, accessibility and long-term usability.

Kee Line Installation for Secondary School Roof Safety in Glasgow - APS Safety 1

Supporting Schools Across Glasgow and Edinburgh

The Glasgow secondary school forms part of a wider programme of roof safety improvements being delivered by APS.

Building on a working relationship that began in 2013, APS is carrying out similar works at multiple schools across Glasgow and Edinburgh, supporting the client with the replacement and upgrading of fall protection and safe access systems.

The continued programme reflects the confidence developed between both organisations over more than a decade of working together.

Further school projects will involve similar assessments of existing systems, followed by recommendations designed around the individual building, its rooftop maintenance requirements and the needs of those responsible for safely accessing the roof.

Conclusion

This project demonstrates APS Safety Systems’ ability to combine technical expertise with a detailed understanding of how fall protection systems are used in practice.

By reviewing the existing arrangements and considering the school’s long-term maintenance requirements, APS was able to replace an ageing horizontal lifeline system with a new Kee Line solution designed to provide more practical rooftop access.

With more than 30 years of industry experience, APS Safety Systems provides fall protection, safe access and working at height solutions for schools, public buildings, commercial properties and industrial facilities throughout Scotland, the wider UK and beyond.

If you are responsible for a building with an ageing or unsuitable horizontal lifeline system, contact APS Safety Systems to discuss an inspection, system upgrade or new Kee Line installation.

Download Case Study Here!

See how APS Safety Systems upgraded roof safety at a Glasgow school with a Kee Line horizontal lifeline system for safe maintenance access.

Click to Download!