
The lattice structure and base ensure the
system cannot be blown over and will
not oscillate.
D-marc has concentrated on designing, manufacturing and marketing performance demarcation barriers that give specifiers the confidence of knowing the system has been tested to withstand some of the harshest weather conditions experienced. The performance has been coupled with sustainability, ease of use and practical barrier installation considerations to ensure a product of outstanding quality that is fit for purpose and looks good.
The D-marc™105 rooftop demarcation barrier system has been wind tunnel tested to withstand wind speeds of up to 105 mph by the BRE and has a patent pending application No. 0802613.0. The stability of the system is due to the unique design of it’s barrier base and upright which eliminates any potential oscillation—a cause of roof surface damage with traditional barrier systems.

Traditional roof demarcation barriers on rooftop applications suffer from instability and wind uplift causing them to fly off roofs at wind speeds as low as 50 mph. Guidance on whether your building will be vulnerable to such wind speeds can be taken from two areas:
The BRE confirms that buildings are generally designed for wind speeds with an annual probability of exceedance of 0.02 i.e. a 1:50 year wind speed. If your rooftop demarcation barrier system is intended to be left on the roof for one year or more, it should meet the same design parameters.
Given that traditional demarcation systems become unstable at wind speeds of 50 mph, it is worth taking a look at the likely incidence of such an occurrence in the UK. If you take a typical UK urban location e.g. Coleshill in the Midlands, figures from the Met office show that over the past 10 years there have been 77 such events.
D-marc™105 is classed as a form of Collective Fall Protection in accordance with the HSE’s hierarchy of risk management as set out within the Working at Height Regulations 2005 (WAHR). The WAHR 2005 Part 3 illustrate the use of demarcation barriers as an “example of taking other additional suitable and sufficient measures to prevent a fall”. The demarcation barrier system is to be placed a safe distance from the fall hazard (normally 2 m).
![]() |
![]() |
| A system to provide a safe route to/from an access stair | A system to provide a safe area for regular maintenance |
Health and Safety in Roofwork HSG33 states that 'where work is not done at the edge, demarcation barriers can be provided at a safe distance from the edge. (usually at least 2 meters). Eg work on an air conditioning unit in the middle of a roof.'


